Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tijdschr Diergeneeskd ; 111(19): 911-20, 1986 Oct 01.
Artigo em Holandês | MEDLINE | ID: mdl-3764871

RESUMO

Dapsone is frequently used as a bacteriostatic drug in the treatment of mastitis, endometritis and footrot (necrotic pododermatitis). The farmer usually obtains this drug by 'non-ethical' channels. A regular scheme of checking the milk for residues of sulphonamides will be introduced in 1986. The sensitivity of the test is approximately 25 ppb for Dapsone. This will result in lower milk price in the case of positive tests. In healthy animals, it is shown that intramuscular treatment with 35 grammes (+/- 70 mg/kg-1 body weight) of Dapsone results in residues of Dapsone and its metabolite monoacetyldapsone above this detection level for more than 6 1/2 days. Within 5 days after oral treatment with 48.75 grammes (+/- 100 mg/kg-1 body weight) and 2 1/2 days after single intramammary treatment with 0.8 grammes, the concentrations of residues detected dropped below 25 ppb. The other well-known metabolite diacetyldapsone was only present in detectable quantities in the first milkings after oral treatment.


Assuntos
Bovinos/metabolismo , Dapsona/metabolismo , Administração Oral , Animais , Dapsona/administração & dosagem , Dapsona/análogos & derivados , Dapsona/análise , Feminino , Injeções Intramusculares , Glândulas Mamárias Animais , Leite/análise , Sulfonamidas/análise
2.
Z Lebensm Unters Forsch ; 183(2): 97-100, 1986 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-3765855

RESUMO

With the described method it is possible to determinate residues of Dapsone (DDS) and its acetylated metabolites (mono- and diacetyldapsone) in milk. The determination is being carried out with a FAST-LC system (Fully Automated Sample Treatment Liquid Chromatography). The purification is a combination of dialysing the milk against water and absorption of the nonpolar components from the dialysate on the preconcentration column of the LC-system used (RP, 40 microns). With back-flush, the concentrate is being injected into the analytical column (RP-8, 5 microns). The detection is being carried out with the help of a UV-absorbance detector, at a wavelength of 296 mm. The detection limit is approximately 2 micrograms/l (DADDS: 5 micrograms/l). The required amount of the sample is 5 ml. The recovery, reproducibility and linearity for the three components in milk are good.


Assuntos
Acedapsona/análise , Dapsona/análogos & derivados , Dapsona/análise , Leite/análise , Animais , Autoanálise , Bovinos , Cromatografia Líquida , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...